Team's Specialty Line Stops
Through-The-Valve-Stop
|
- Ideal for non-functioning valves on tanks and vessels.
- Special machine is installed to an existing valve.
- The damaged valve is removed and a new valve installed.
- The special machine is removed.
|
|
Across-The-Header-Stop
- When the clearance limitation will not allow normal line stopping methods.
- A SealTite® fitting is welded to the header and a valve installed.
- A hot tap is made and the plug is set.
- When the repairs are complete the Sealtite® completion plug is set.
|
|
Elbow Stop
- A special SealTite® fitting is installed to the elbow.
- An angle tap is performed on the elbow through a temporary valve.
- The line stop is set and the defective valve replaced.
- Team's SealTite® completion plug is set and the temporary valve removed.
|
|
Tee Stop
- A special SealTite® fitting is installed to the backside of the Tee.
- A temporary valve is installed and a hot tap performed.
- The line stop plug passes through the Tee and is set into the outlet.
- The SealTite® completion plug is set and the temporary valve removed.
|
|
|
|
|
|
Double Line Stop
|
|
Triple Line Stop
|
|
Bag Stop
|
HOME